Ultrasound inspection
![]() |
![]() |
![]() |
![]() |
![]() |
Applications:
- Loading lines for crude oil and liquid oil products
- Connecting pipes between offshore oil platform and treatment platform
- Seawater intakes for use with crude oil production
Technical data as an overview:
- Rotating ultrasound sensors for variable resolution
- Operation range 8" - 48", other pipeline ranges on inquiry
- Measuring values: inner pipe contour, remaining wall thickness
- Measurable damages: dents, interior and exterior corrosion, laminations, deformations
- Minimum wall thickness >2mm
- Measuring accuracy: +/- 0.1mm
|
|
|
|
Please send us your inquiry for whall thickness measurement. Please contact us. ![]()